Procedure to Change the Date and time in Siemens Hipath 4000 Series 3000 Series IP EPBX
To display the date
# DIS-DATE;
H500: AMO DATE STARTED
+—————————–+
| TUESDAY |
| DATE: TIME : |
| 2011-03-31 14:30:05 |
| |
| NUMBER OF DAY : 90 |
| NORMAL TIME |
| GMTDIR: EAST TIMEOFFS:330 |
| DSTOFFS:0 |
| REL. DIFF. TO GMT : +330 |
+—————————–+
AMO-DATE -111 TIME AND DATE
DISPLAY COMPLETED;
To change the date
# cha-date
and follow the instructions
To see the options type ?
GMTDIR = ?
GMTDIR : DIRECTION RELATED TO GMT
CHARACTERISTIC : REQUIRED
POSS. VALUES : EAST TIME OFFSET WILL BE ADDED
WEST TIME OFFSET WILL BE SUBTRACTED
UTC TIME OFFSET WILL BE IGNORED
GMTDIR = EAST
TIMEOFFS = ?
TIMEOFFS : TIME OFFSET IN MINUTES
CHARACTERISTIC : REQUIRED
POSSIBLE VALUES : 0-1440
TIMEOFFS = 330
#CHA-DATE:EAST,330,NT,0;
This will set the date to GMT : +330 offset
For GMT : -530 offset, run the below command.
#CHA-DATE:WEST,530,NT,0;
and how i can change the time?
I mean, change hour and minutes.
Thanks
I think time will be calculated from system clock. You have to set the time offset (like GMT : +330).
#CHA-DATE:EAST,330,NT,0;